BP2000Ø_8*4GYJ5D510 (110,400kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*13,800 = 13,800kN
YJACK Capacity in BD-Load = 8*13,800= 110,400kN
YJACK Test Range in BD-Load = 0 to 110,400kN


Tremie Hole = 830mm
Loading Area = 52.0%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM242,880.00

YCELL Capacity in BD = 1*13,800 = 13,800kN
YJACK Capacity in BD = 8*13,800 = 110,400kN
0 < Applied Load (BD) <= 110,400

8*4GYJ5D510
Tremie Hole = 830mm
Loading Area = 52.0%
Orbit Radius = 818.65mm