Bored Pile BP1500
BP1500Ø_8*5GYJ3D325 (36,800kN)
Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made
YCELL Capacity in BD-Load = 8*2,300 = 18,400kN
YJACK Capacity in BD-Load = 8*4,600 = 36,800kN
YJACK Test Range in BD-Load = 0 to 36,800kN
Tremie Hole = 500mm
Loading Area = 37.6%
Concrete Cover = 75mm
Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)
Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor
BP1500Ø_7*5GYJ3D325 (32,200kN)
Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made
YCELL Capacity in BD-Load = 7*2,300 = 16,100kN
YJACK Capacity in BD-Load = 7*4,600 = 32,200kN
YJACK Test Range in BD-Load = 0 to 32,200kN
Tremie Hole = 500mm
Loading Area = 32.9%
Concrete Cover = 75mm
Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)
Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor
BP1500Ø_6*5GYJ3D325 (27,600kN)
Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made
YCELL Capacity in BD-Load = 6*2,300 = 13,800kN
YJACK Capacity in BD-Load = 6*4,600 = 27,600kN
YJACK Test Range in BD-Load = 0 to 27,600kN
Tremie Hole = 500mm
Loading Area = 28.2%
Concrete Cover = 75mm
Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)
Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor
BP1500Ø_5*5GYJ3D325 (23,000kN)
Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made
YCELL Capacity in BD-Load = 5*2,300 = 11,500kN
YJACK Capacity in BD-Load = 5*4,600 = 23,000kN
YJACK Test Range in BD-Load = 0 to 23,000kN
Tremie Hole = 500mm
Loading Area = 23.5%
Concrete Cover = 75mm
Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)
Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor
BP1500Ø_8*5GYJ5D340 (47,200kN)
Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made
YCELL Capacity in BD-Load = 8*2,950 = 23,600kN
YJACK Capacity in BD-Load = 8*5,900 = 47,200kN
YJACK Test Range in BD-Load = 0 to 47,200kN
Tremie Hole = 500mm
Loading Area = 41.1%
Concrete Cover = 75mm
Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)
Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor
BP1500Ø_7*5GYJ5D340 (41,300kN)
Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made
YCELL Capacity in BD-Load = 7*2,950 = 20,650kN
YJACK Capacity in BD-Load = 7*5,900 = 41,300kN
YJACK Test Range in BD-Load = 0 to 41,300kN
Tremie Hole = 500mm
Loading Area = 36.0%
Concrete Cover = 75mm
Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)
Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor
- 1
- 2