Ecommerce

Bored Pile BP1500mm

View as Grid List
Sort by
Display per page

BP1500Ø_5*4GYJ2D425 (23,500kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*4,700 = 4,700kN
YJACK Capacity in BD-Load = 5*4,700 = 23,500kN
YJACK Test Range in BD-Load = 0 to 23,500kN


Tremie Hole = 500mm
Loading Area = 40.1%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM51,700.00

BP1500Ø_5*4GYJ2D425s (26,000kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*5,200 = 5,200kN
YJACK Capacity in BD-Load = 5*5,200 = 26,000kN
YJACK Test Range in BD-Load = 0 to 26,000kN


Tremie Hole = 500mm
Loading Area = 40.1%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM57,200.00

BP1500Ø_5*4GYJ3D425 (30,000kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*6,000 = 6,000kN
YJACK Capacity in BD-Load = 5*6,000 = 30,000kN
YJACK Test Range in BD-Load = 0 to 30,000kN


Tremie Hole = 500mm
Loading Area = 40.1%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM66,000.00

BP1500Ø_5*4GYJ4D425 (35,000kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*7,000 = 7,000kN
YJACK Capacity in BD-Load = 5*7,000 = 35,000kN
YJACK Test Range in BD-Load = 0 to 35,000kN


Tremie Hole = 500mm
Loading Area = 40.1%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM77,000.00

BP1500Ø_5*4GYJ5D440 (45,000kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*9,000 = 9,000kN
YJACK Capacity in BD-Load = 5*9,000 = 45,000kN
YJACK Test Range in BD-Load = 0 to 45,000kN


Tremie Hole = 470mm
Loading Area = 43.0%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM99,000.00

BP1500Ø_6*4GYJ2D425 (28,200kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*4,700 = 4,700kN
YJACK Capacity in BD-Load = 6*4,700 = 28,200kN
YJACK Test Range in BD-Load = 0 to 28,200kN


Tremie Hole = 500mm
Loading Area = 48.2%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM62,040.00