This bi-directional pile test system application is for Bi-Directional Pile Load Test, Type B (bored pile).
Competency Level:
OJACK360 Type B Welder Competency: general welder
OJACK360 Type B Installer Competency: OJACK360 Installer, Competency Level L2 and above
OJACK360 Type B Tester Competency: Pile Test Engineer, Competency Level L3 and above
| Name | Value |
|---|
| OCELL360 Jack Model | DONUT6D665L |
| OCELL360 Jack Capacity | 1*4,300 = 4,300kN in F(1D) |
| OCELL360 Jack Capacity | 2*4,300 = 8,600kN in F(BD) |
| OCELL360 Jack Quantity | 1 |
| OJACK360 Jack Capacity | 1*8,600 = 8,600kN in F(BD) |
| OJACK360 Test Range | 0 to 8,600kN in F(BD) |
| OJACK360 Outer Diameter | 1050mm |
| OJACK360 Ram Stroke | 110mm |
| Tremie Hole | 340mm |
| Concrete Cover | 75mm |