This bi-directional pile test system application is for Bi-Directional Pile Load Test, Type B (bored pile).
Competency Level:
OJACK360 Type B Welder Competency: general welder
OJACK360 Type B Installer Competency: OJACK360 Installer, Competency Level L2 and above
OJACK360 Type B Tester Competency: Pile Test Engineer, Competency Level L3 and above
Name | Value |
---|
OCELL360 Jack Model | DONUT6D665 |
OCELL360 Jack Capacity | 1*7,100 = 7,100kN in F(1D) |
OCELL360 Jack Capacity | 1*7,100 = 14,200kN in F(BD) |
OCELL360 Jack Quantity | 1 |
OJACK360 Jack Capacity | 1*14,200 = 14,200kN in F(BD) |
OJACK360 Test Range | 0 to 14,200kN in F(BD) |
OJACK360 Outer Diameter | 1050mm |
OJACK360 Ram Stroke | 110mm |
Tremie Hole | 340mm |
Concrete Cover | 75mm |