This bi-directional pile test system application is for Bi-Directional Pile Load Test, Type B (bored pile).
Competency Level:
OJACK360 Type B Welder Competency: general welder
OJACK360 Type B Installer Competency: OJACK360 Installer, Competency Level L2 and above
OJACK360 Type B Tester Competency: Pile Test Engineer, Competency Level L3 and above
Name | Value |
---|
OCELL360 Jack Model | FLAT3D325 |
OCELL360 Jack Capacity | 1*2,300 = 2,300kN in F(1D) |
OCELL360 Jack Capacity | 2*2,300 = 4,600kN in F(BD) |
OCELL360 Jack Quantity | 8 |
OJACK360 Jack Capacity | 8*4,600 = 36,800kN in F(BD) |
OJACK360 Test Range | 0 to 36,800kN in F(BD) |
OJACK360 Outer Diameter | 1350mm |
OJACK360 Ram Stroke | 110mm |
Tremie Hole | 430mm |
Concrete Cover | 75mm |