Ecommerce

YJACK

YJACK, Malaysian Brand, World Patents, The World’s Best Pile Load Test.

View as Grid List
Sort by
Display per page

BP1200Ø_5*4GYJ2D325 (13,500kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*2,700 = 2,700kN
YJACK Capacity in BD-Load = 5*2,700 = 13,500kN
YJACK Test Range in BD-Load = 0 to 13,500kN


Tremie Hole = 400mm
Loading Area = 36.7%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM29,700.00

BP1200Ø_5*4GYJ2D325s (16,500kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*3,300 = 3,300kN
YJACK Capacity in BD-Load = 5*3,300 = 16,500kN
YJACK Test Range in BD-Load = 0 to 16,500kN


Tremie Hole = 400mm
Loading Area = 36.7%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM36,300.00

BP1200Ø_5*4GYJ3D325 (20,000kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*4,000 = 4,000kN
YJACK Capacity in BD-Load = 5*4,000 = 20,000kN
YJACK Test Range in BD-Load = 0 to 20,000kN


Tremie Hole = 400mm
Loading Area = 36.7%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM44,000.00

BP1200Ø_5*4GYJ4D325 (24,000kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*4,800 = 4,800kN
YJACK Capacity in BD-Load = 5*4,800 = 24,000kN
YJACK Test Range in BD-Load = 0 to 24,000kN


Tremie Hole = 400mm
Loading Area = 36.7%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM52,800.00

BP1200Ø_5*4GYJ5D340 (31,000kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: PayPal or COD (via local bank transfer)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*6,200 = 6,200kN
YJACK Capacity in BD-Load = 5*6,200 = 31,000kN
YJACK Test Range in BD-Load = 0 to 31,000kN


Tremie Hole = 370mm
Loading Area = 40.1%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM68,200.00

BP1200Ø_6*4GYJ2D325 (16,200kN)

Shipment Method: Self Pick-Up or Ground Transportation (by 3rd party)
Payment Method: Local Cheque Deposit (CD) or Local Bank Transfer (TT)
Delivery Time: 3 Working Days after successful payment made


YCELL Capacity in BD-Load = 1*2,700 = 2,700kN
YJACK Capacity in BD-Load = 6*2,700 = 16,200kN
YJACK Test Range in BD-Load = 0 to 16,200kN


Tremie Hole = 400mm
Loading Area = 44.0%
Concrete Cover = 75mm


Fabrication Method: DIY by Welder, Competency Level L1 (do it yourself)
Installation Method: DIY by Installer, Competency Level L2 (do it yourself)
Testing Method: DIY by Tester, Competency Level L2 (do it yourself)


Hydraulic Hoses: included (length = pile top to balance level + 5m)
Telltale Wires: included (length = pile top to balance level + 5m)
Grouting Pipes: sonic logging pipes or poly pipes by contractor

RM35,640.00