This bi-directional pile test system application is for Bi-Directional Pile Load Test, Type B (bored pile).
Competency Level:
YJACK360 Type B Welder Competency: general welder
YJACK360 Type B Installer Competency: YJACK360 Installer, Competency Level L2 and above
YJACK360 Type B Tester Competency: Pile Test Engineer, Competency Level L3 and above
Name | Value |
---|
YCELL360 Jack Model | FLAT3D325 |
YCELL360 Jack Capacity | 1*2,300 = 2,300kN in F(1D) |
YCELL360 Jack Capacity | 2*2,300 = 4,600kN in F(BD) |
YCELL360 Jack Quantity | 5 |
YJACK360 Jack Capacity | 5*4,600 = 23,000kN in F(BD) |
YJACK360 Test Range | 0 to 23,000kN in F(BD) |
YJACK360 Outer Diameter | 1200mm |
YJACK360 Ram Stroke | 110mm |
Tremie Hole | 500mm |
Concrete Cover | 75mm |