This bi-directional pile test system application is for Bi-Directional Pile Load Test, Type B (bored pile).
Competency Level:
YJACK360 Type B Welder Competency: general welder
YJACK360 Type B Installer Competency: YJACK360 Installer, Competency Level L2 and above
YJACK360 Type B Tester Competency: Pile Test Engineer, Competency Level L3 and above
Name | Value |
---|
YCELL360 Jack Model | DONUT6D825 |
YCELL360 Jack Capacity | 1*11,000 = 11,000kN in F(1D) |
YCELL360 Jack Capacity | 2*11,000 = 22,000kN in F(BD) |
YCELL360 Jack Capacity | 1 |
YJACK360 Jack Capacity | 1*22,000 = 22,000kN in F(BD) |
YJACK360 Test Range | 0 to 22,000kN in F(BD) |
YJACK360 Outer Diameter | 825mm |
YJACK360 Ram Stroke | 110mm |
Tremie Hole | 340mm |
Concrete Cover | 75mm |