This bi-directional pile test system application is for Bi-Directional Pile Load Test, Type B (bored pile).
Competency Level:
YJACK360 Type B Welder Competency: general welder
YJACK360 Type B Installer Competency: YJACK360 Installer, Competency Level L2 and above
YJACK360 Type B Tester Competency: Pile Test Engineer, Competency Level L3 and above
Name | Value |
---|
YCELL360 Jack Model | DONUT6D825L |
YCELL360 Jack Capacity | 1*8,600 = 8,600kN in F(1D) |
YCELL360 Jack Capacity | 2*8,600 = 17,200kN in F(BD) |
YCELL360 Jack Capacity | 1 |
YJACK360 Jack Capacity | 1*17,200 = 17,200kN in F(BD) |
YJACK360 Test Range | 0 to 17,200kN in F(BD) |
YJACK360 Outer Diameter | 825mm |
YJACK360 Ram Stroke | 110mm |
Tremie Hole | 430mm |
Concrete Cover | 75mm |